The local date and time is stored in system memory. Adjust date and
time after long power-failure.
LED Indicators
Four LEDs provide visual indication of System status, as well as confirmation of
various modes.
Red ARMED/ALARM Indicator
- Lights up when system is armed and blinks
after an alarm is triggered at any zone. Blinking indicates alarm history in memory.
Green STATUS Indicator
- Blinks when zone/s is/are troubled, remains lit as
long as zones are not troubled, quick blinking indicates Tamper alarm.
Yellow SHUNT (Bypass) Indicator
- Lights up upon zone bypass.
(Note: May lights automatically upon arming if Auto Bypass was programmed).
The indicator also lights and blinks upon Group Bypass entry (by pressing ‘0’ twice).
Red FIRE (Trouble) Indicator
- quick blinking when a Fire Zone is troubled.
 Two LEDs Flashing (Left Most LEDs)
- In user code programming mode,
quick blinking indicates code or code index to be entered.
In Disarmed mode, the two left-most LEDs are blinking to indicate 24H-alarm mode.
Zone number will also be displayed.
 Three LEDs Flashing
- In Disarmed mode, quick blinking indicates AC
power failure. AC power failure event is displayed in Events History as three lines
{
.
In Armed mode, rapid blinking indicates system restored after AC Power Failure
mode.
During programming the Follow-Me Telephone Number, three flashing LEDs
indicate that system is expecting a new telephone number.
 Four LEDs Flashing
- Upon holding-down key ‘8,’ the system is ready for
code to be entered.
System with bypass via code: Same LED indication when code is expected for Bypass
via code.)
Keypad display
The 7-segment display provides visual readout of system status. The display indicates
zones in alarm, troubled zones, bypassed zones and displays the following
confirmation letters:
Display Description Function
A Up & Download
Modem ‘Answer Now’ function selected. Confirms hold-
down ‘6’ key then hold-down ‘1’ key.
‘A’ also displayed upon Auto-Arming programming
C Communication
Displayed at dialer tests, and upon holding-down ‘6’ key
C Communication
C flashing in display indicates telephone line trouble