AV-702 keypad contains identical keys and LED structure to AV-701.
The Status LED is on
when all the zones
are close.
The Red Armed LED
is on when the system
is armed.
The Shunt LED
indicates that a zone
is bypassed.
Blinking ‘h’ means
that the system time
is not set; hold-down
key ’1’ key then ’0’, three LEDs are blinking, enter time in 24 hours format.
Hold-down functions
To hold-down function access, hold down the key for approximately 2 seconds.
Hold down function is confirmed by a prolonged beep. Refer to hold-down list:
1
- Siren Test
2
- Display Bypassed
Zones
3
- Display Troubled
Zones
4
- Delay Delete
5
- Activate Chime
6
- Tel. Programming
7
- Zone Test
8
- Code Programming
9
- Delete Last key Press
0
– Display Alarm History
*
and #
- Panic
0
Shunt
and
1
Siren
Display and Setting of System Time:
Hold down ‘0’ key
and then hold-down ‘1’, three LEDs are blinking, wait for the time to be displayed in
4-digits format.
To set new time, hold down key ‘0’ and then hold down ‘1’. Do not wait for time
display; enter the new time in 24-hours format. The local clock time is not stored in
the system memory; clock must be adjusted after power-up. After powering-up the
system, time is reset to 00:00, ‘h’ will be displayed to remind user to set time; ‘h’ will
disappear after the new time is set.
0
Shunt
and
2
Shunt
Display
Display and Setting of System Date:
Hold down ‘0’ key
and then hold-down ‘2’; 3 LEDs will blink. Enter date: ‘dd mm yy.’ The up and
download PC software displays time and date, along with history event.
Years 1978 through 99 as 78 to 99. Years 2000 through 2077 00 to 77
*
7
4
1
0
8
5
2
#
9
6
3
Siren
Shunt
Display
Status
Delay
Delete
Chime
Test
Pro
ram
Shunt
Telephone
ARMED STATUS SHUNT FIRE
ZONE
DISPLAY